LIGNUM – Holzwirtschaft Schweiz | Economie suisse du bois | Economia svizzera del legno
Mühlebachstrasse 8 | 8008 Zürich | Tel. 044 267 47 77 | Fax 044 267 47 87 | info@lignum.ch

> Printversion

Components

Construction assembly D0255

Lignum ID-№
D0255
Catalog number
D.1.02.E13
Source of construction assembly
Lignum, Year 2016
Base structure
Stud
Type of facade
Ventilated facade and wall covering
Paneling
Substructure rigid screwed
Construction height
405 mm
Weight
70 kg/m2
U-value
≈ 0.133 W/m2K
GWP
33.20 kg CO2-eq/m2
Type sound insulation
Verified calculation
Outer wall consisting of a basic construction of stud with cavity insulation in the supporting structure with air flow resistivity [r] of 5≤ r ≤50 kPa s/m². Sheathed outside & interior, on the outside single sheathed, roomside single sheathed. Simple covering with cavity insulation. Ventilated facade.
Values of airborne sound insulation
Rw 47 dB
C -2 dB
Ctr -8 dB

Comment Der Einsatz der geeigneten Dampfbremse und der Fassadenbahn ist Projektbezogen zu klären.

Graphic

Assembly

Layer Product Manufacturer Thickness [mm] Weight Width (b) Axial distance (e) KBOB ID-№ Production KBOB ID-№ Disposal

Ecological indicators according to the KBOB life cycle assessment data in the construction sector KBOB / ecobau / IPB 2009/1:2022, Version 6
(For the life cycle phases production and disposal, excluding the construction phase (Modules A4, A5) and the use phase (Module B), especially replacement (Module B4) or amortization periods according to SIA 2032)

bSDD Properties
mm Indicators Modules
Values / m2
+
Environmental impact points (UBP)
62041
UBP'21/m2
A1-A3 + C1-C4
 
Environmental impact points from production (UBP_pro)
54818
UBP'21/m2
A1-A3
 
Environmental impact points from disposal (UBP_dis)
7236
UBP'21/m2
C1-C4
+
Total primary energy (PE_T)
481.60
kWh oil-eq/m2
A1-A3 + C1-C4
 
Primary energy from production (PE_pro)
474.70
kWh oil-eq/m2
A1-A3
 
Primary energy production, energetically consumed (PE_E_pro)
231.40
kWh oil-eq/m2
A1-A3
 
Primary energy production, materially bound (PE_M_pro)
242.60
kWh oil-eq/m2
A1-A3
 
Primary energy from disposal (PE_dis)
7.60
kWh oil-eq/m2
C1-C4
+
Renewable primary energy (PE_RT)
332.10
kWh oil-eq/m2
A1-A3 + C1-C4
 
Renewable primary energy from production (PE_RT_pro)
331.50
kWh oil-eq/m2
A1-A3
 
Renewable primary energy from generation, energetically consumed (PE_RE_pro)
101.30
kWh oil-eq/m2
A1-A3
 
Renewable primary energy from production, materially bound (PE_RM_pro)
230.20
kWh oil-eq/m2
A1-A3
 
Renewable primary energy from disposal (PE_RT_dis)
0.50
kWh oil-eq/m2
C1-C4
+
Total use of non- renewable primary energy resources (PE_NRT)
149.50
kWh oil-eq/m2
A1-A3 + C1-C4
 
Primary energy not renewable from manufacturing (PE_NRT_pro)
142.40
kWh oil-eq/m2
A1-A3
 
Primary energy not renewable from production, energetically consumed (PE_NRE_pro)
130.20
kWh oil-eq/m2
A1-A3
 
Primary energy not renewable from production, materially bound (PE_NRM_pro)
12.30
kWh oil-eq/m2
A1-A3
 
Primary energy not renewable from disposal (PE_NRT_dis)
7.10
kWh oil-eq/m2
C1-C4
+
Total greenhouse gas emissions (GWP_total)
33.20
kg CO2/m2
A1-A3 + C1-C4
 
Greenhouse gas emissions from manufacturing (GWP_pro)
29.60
kg CO2/m2
A1-A3
 
Greenhouse gas emissions from waste disposal (GWP_dis)
3.60
kg CO2/m2
C1-C4
 
Biogenic carbon dioxide storage (bio-C x 44/12 = bio-CO2) (Not included in GWP)
75.90
kg CO2/m2
B1-B7
 
Biogenic carbon storage (bio-C) (Not included in GWP)
20.70
kg C/m2
B1-B7
⇒ Advantages of the life cycle assessment outside the system boundary (module D)